LEGEND:
1 Tank cover;
2 ceramic cover;
3 inspection cover;
4 tube bundle;
5 litre expansion tank (for tank protection)
6 tube bundle lever;
7 control panel;
8 riddling handle;
9 adjustable mounting feet;
10 smoke side pressure switch;
11 ratiomotor and lever for automatic cleaning of brazier;
12 boiler drain cock with flex tube connection;
13 patented self-cleaning burner;
14 smoke suction unit;
15 ash pans;
16 system circulating pump;
17 smoke outlet;
18 steam relief valve;
19 sump for temperature feeler and safety thermostat;
20 safety thermostat;
21 pressure transducer;
22 electronic board;
23 safety valve calibrated at 3 bar;
24 water delivery;
25 water return;
26 boiler fill-up cock;
27 tank
|
|
 |
Dimensions (HxWxD) |
(mm)
|
1214-616-700 |
 |
Electric consumption (min/max) |
(W)
|
65-130 |
 |
Efficiency until |
|
∼90% |
 |
Min. flue draught pressure |
(mbar)
|
0,10 |
 |
High temperature safety thermostat |
|
|
 |
Flue gasexhaust diameter |
(mm)
|
80 |
 |
Pellet hopper capacity |
(kg)
|
43 |
 |
Hourly pellet consumption |
(kg/h)
(min/max)
|
0,8-3,5* |
 |
Refuelling cycle (min/max) hours |
(h)
|
53-12 |
 |
Noise at min. |
(db)
|
38 |
 |
5 levels of temperature control
|
|
|
 |
System circulating pump
|
|
|
 |
Expansion tank |
|
|
 |
Safety valve |
|
|
 |
Weekly programmer |
|
|
 |
Patented Burner |
|
• |
 |
Radio control with room temperature thermostat
|
|
• |
 |
Voice function |
|
• |
 |
Room thermostat |
|
optional |
 |
G.S.M. Moden system. |
|
optional |
 |
Weight |
(kg)
|
209-235 |
 |
Power to the hearth |
(kW) |
3,1-18 |
 |
Power rendered for convection and radiation of the atmosphere
|
(kW) |
2,5 |
 |
Power to the water |
(kW) |
12,5 |
 |
Instant domestic hot water production kit |
|
optional |
*The declared consumption can change on the basis of the pellet used - All the figures were measured using approved pellets in compliance with O M 7135
|
|