WOOD Boilers - ASPIROMEC

TECHNICAL CHARACTERISTICS
ASPIROMEC
LE 35
ASPIROMEC
LE 54
ASPIROMEC
LE 73
A 623 713 713
B / / /
C 1303 1435 1435
E 696 820 1354
F 37 37 37
G 827 909 1479
I 1140 1270 1270
L 1080 1210 1210
M 140 145 145
N 112 122 122
N1 230 304 375
N2 / / 515
O 1048 1176 1048
1108 1236 1236
R 33 33 33
T 600 980 925
X 156 156 221
Z 775 865 865
W / / /
Weight Kg. 430 615 915
FLUE OUTLET CONNECTION mm 180 180 200
FEED DOOR DIMENSIONS 324x234 354x264 354x264
FUEL FEED CHAMBER VOLUME dm3 solidi 98 166 315
Water content lt solidi
fluidi
83 150 225
OPERATING PRESSURE bar solidi
fluidi
3 3 3
MAX. FIREWOOD LENGTH mm S 530 530 1000
FLUE OUTLET VACUUM mbar S/F -0,15 -0,15 -0,15
HEAT EXCHANGER CONNECTIONS Ø S 1/2" 1/2" 1/2"
HEAD LOSS water side mbar 0,15 0,6 3,43
COLD WATER PRESSURE REQUIRED BY THE EXCHANGER 2 2 2
DELIVERY CONNECTIONS Ø solidi
fluidi
1" 1/2 1" 1/2 2"
RETURN CONNECTIONS Ø solidi
fluidi
1"1/2 1" 1/2 2"
Power to the hearth kcal/h
kW
20.800
24
46.800
54
88.400
102
USEFUL POWER kcal/h
kW
17.300
30
38.100
44
71.000
82
Power to the hearth GAS/ DIESEL OIL kcal/h
kW
/ / /
Power to the hearth GAS/ DIESEL OIL kcal/h
kW
/ / /
*heat loss calculated to Qn with a heat drop of 15°C.

The technical data and characteristics are subject to changes




THERMOROSSI s.p.a. - 36011 ARSIERO (VI) Italy - Via Grumolo, 4 (Zona Ind.)
Fax: (+39) 0445 741657 - www.thermorossi.com