Loading...

Aspiromec LE73

Inverted flame log boilers
 
The Aspiromec LE model is fitted with a patented burning pot and with an elecctromechanically controlled suction unit for evacuating the exhaust gases and drawing in the air required for the combustion process at the same time. Operation is ON/OFF depending on the generator temperature and withour power modulation. The suction unit solves flue outlet draught problems which are now no longer critical for boiler operation. The use of the control panel and of the application functions is deliberately simple. Vitrification  (optional).
Heatable area
531 .
  • Orange
 


1 - The high insulation layer of coating guarantees the lowest level of heat loss
2 - Pipes heat exchanger easy to clean
3 - Centrifugal fan for extracting smokes
4 - Safety copper heat exchanger
5 - Anti-burn door handle
6 - Wide heat exchange thanks to the wide water jacket
7 - Primary and secondary air control system
8 - «LE» patented burner for inverted flame combustion
9 - Wide firebox with thermic stone base
10 - Wide cast iron ash pan

Heat exchanger Thermocore® Higher heat accumulation Simplified cleaning system 8 Years Made in Italy



OPTIONAL ACCESSORIES




Dimensions
  • thermorossi_dimension_aspiromec_le
Technical data
DIMENSIONS (HXWXD)    1478x865x1426
WEIGHT (kg)    695
HEATABLE AREA (m²)*a*c    531
EFFICIENCY UP TO MAX (%)*a    80,8%
ENERGY CLASS    A+
POWER TO THE HEART (kW)*a    73,0
RATED POWER (kW)*a    59,0
POWER TO THE WATER (kW)*a    59,0
RADIATION (kW)*a    -
HOURLY PELLET CONSUMPTION (kg/h)*a    -
WOOD HOURLY CONSUMPTION (kg/h)*a    0 - 17,8
PELLET HOPPER CAPACITY (kg)*a   
WARM AIR DUCTING    -
MAXIMUM SINGLE DUCTING OUTLET (m)    -
PATENTED BURNER PELLETPOWER®   
ROOM VENTILATION    -
PRIMARY AIR FROM OUTSIDE    -
CO EMISSIONS (mg/m³; 13% of O2)*a   
CO EMISSIONS (mg/m³; 10% of O2)*a    -
DUST EMISSIONS (mg/m³; 13% of O2)*a   
DUST EMISSIONS (mg/m³; 10% of O2)*a    -
SILENCE (dB)    -
REMOTE CONTROL    -
RADIO CONTROL WITH ROOM TEMPERATURE THERMOSTAT    -
WEEKLY PROGRAMMER (3 DAILY LIGHTING)    -
«SMART INFO» FUNCTION    -
SYSTEM CIRCULATING PUMP    -
EXPANSION TANK    -
OVER PRESSURE VALVE    -
FLUE GASEXHAUST DIAMETER (mm)    200
MIN. FLUE DRAUGHT PRESSURE (Pa)    15
ELECTRIC CONSUMPTION (Watt)    -
HIGH TEMPERATURE SAFETY THERMOSTAT    -
*A Emissions and performance data may change according to the fuel used. The values of pellet products have been obtained by using certified fuel according to EN 14961-2 A1-A2 norm. Wood logs products values may vary according to the type and quality of the wood logs used.
*B Provisional data under certification
*C IMPORTANT: when calculating the volume of the “Heated area” some relevant aspects must be considered: insulation of the building (Energy Class), position of the heater, climatic area and more aspects that can affect the values of performance. Reported data have been calculated on the base of roof not higher than 3 mts.
The manufacturer reserves the right to make changes without previous notice.
Downloadable docs
Energy label Aspiromec LE 73