Loading...

Flam Easy

Air-ducting pellet stove
 
Inspired by the tiny Norwegian fairy-tale village, Flåm, which is located along a fjord, snuggled between birch forests and hundreds of waterfalls. Hermetically sealed and ductable pellet stove fitted with a self-cleaning burner with up to 500 hours NON-STOP operation. Emotional flame, Natural function at any power, tube heat exchanger, easy routine and extraordinary cleaning, provision for Wi-Fi technology.
Heatable area
86 .
  • nero opaco
 


1 - Control for ducting outlet
2 - Sliding cast iron top with Natural function at any power
3 - THERMOCORE® pipe heat exchanger
4 - Pelletpower® patented self-cleaning burner

Every uniti s tested for one hour in the factory Our products don’t incur additional cost for adjustments or testing Simplified cleaning system Heat exchanger Thermocore® External rotor room fan is guaranteed for 4 years Higher heat accumulation Thermosilent system Air ducting product Mechanical-safety-devices Madaly Pelletpower® - Patented burner External primary air input Crono_36x36 Tubo_coassiale_36x36 fiamma emozionale thermorossi_plus_wifi_technology_36x36





Dimensions
  • Flam Easy
Technical data
DIMENSIONS (HXWXD)    1085x514x572
WEIGHT (kg)    160
HEATABLE AREA (m²)    86
EFFICIENCY UP TO MAX (%)    91,6%
ENERGY CLASS    A+
POWER TO THE HEART (kW)    2,5 - 10,4
RATED POWER (kW)    2,3 - 9,5
POWER TO THE WATER (kW)     -
RADIATION (kW)    2,3 - 9,5
HOURLY PELLET CONSUMPTION (kg/h)    0,5 - 2,2
WOOD HOURLY CONSUMPTION (kg/h)     -
PELLET HOPPER CAPACITY (kg)    17,4
WARM AIR DUCTING    SI
MAXIMUM SINGLE DUCTING OUTLET (m)    15,00
PATENTED BURNER PELLETPOWER®    -
ROOM VENTILATION    SI
PRIMARY AIR FROM OUTSIDE    SI
CO EMISSIONS (mg/m³; 13% of O2)    31,0
CO EMISSIONS (mg/m³; 10% of O2)    -
DUST EMISSIONS (mg/m³; 13% of O2)    14,0
DUST EMISSIONS (mg/m³; 10% of O2)    -
SILENCE (dB)    36
REMOTE CONTROL    -
RADIO CONTROL WITH ROOM TEMPERATURE THERMOSTAT    -
WEEKLY PROGRAMMER (3 DAILY LIGHTING)    SI
«SMART INFO» FUNCTION    SI
SYSTEM CIRCULATING PUMP    -
EXPANSION TANK    -
OVER PRESSURE VALVE    SI
FLUE GASEXHAUST DIAMETER (mm)    80
MIN. FLUE DRAUGHT PRESSURE (Pa)    9
ELECTRIC CONSUMPTION (Watt)    70 - 270
HIGH TEMPERATURE SAFETY THERMOSTAT    SI
Downloadable docs
Manuale Rivestimento Flam_ENG
Manuale Flam - Movida_ENG
EU Declaration of Conformity_Flam - Movida
Product Fiche_Flam - Movida
Energy Label_FLAM
Dop_FLAM
Report BlmSchV_Flam - Movida
Report DK_Flam - Movida
Report Ecodesign_Flam - Movida
Report CE_Flam - Movida

Need help?