Loading...

800 ov

Wood stove
 
Model 800 features a casing of majolica tiles with an oval motif, has hot air channelling capability and a food warmer to accommodate both traditional usage and modern requirements. Heat can be distributed to a number of rooms by the simple application of an AIRBOX.
Heatable area
98 .
  • Leather
  • Bordeaux
  • Beige
  • Desert Sand
 


1 - Food warming compartement
2 - Large combustion chamber (HxLxD-430x393x355)
3 - Cool touch door handle
4 - Removable ash tray
5 - Cast iron ash collecting base

Higher heat accumulation Simplified cleaning system Hot plate External primary air input Made in Italy



OPTIONAL ACCESSORIES




Dimensions
  • thermorossi_dimension_800_OV
Technical data
DIMENSIONS (HXWXD)    1193x616x573
WEIGHT (kg)    221
HEATABLE AREA (m²)*a*c    98
EFFICIENCY UP TO MAX (%)*a    70,0%
ENERGY CLASS    A
POWER TO THE HEART (kW)*a    15,6
RATED POWER (kW)*a    10,9
POWER TO THE WATER (kW)*a    -
RADIATION (kW)*a    10,9
HOURLY PELLET CONSUMPTION (kg/h)*a    -
WOOD HOURLY CONSUMPTION (kg/h)*a    3,7
PELLET HOPPER CAPACITY (kg)*a   
WARM AIR DUCTING    OPT (8m)
MAXIMUM SINGLE DUCTING OUTLET (m)    -
PATENTED BURNER PELLETPOWER®   
ROOM VENTILATION    OPT
PRIMARY AIR FROM OUTSIDE    SI
CO EMISSIONS (mg/m³; 13% of O2)*a    1.694,0
CO EMISSIONS (mg/m³; 10% of O2)*a   
DUST EMISSIONS (mg/m³; 13% of O2)*a    -
DUST EMISSIONS (mg/m³; 10% of O2)*a   
SILENCE (dB)    -
REMOTE CONTROL    -
RADIO CONTROL WITH ROOM TEMPERATURE THERMOSTAT    -
WEEKLY PROGRAMMER (3 DAILY LIGHTING)    -
«SMART INFO» FUNCTION    -
SYSTEM CIRCULATING PUMP    -
EXPANSION TANK    -
OVER PRESSURE VALVE    -
FLUE GASEXHAUST DIAMETER (mm)    150
MIN. FLUE DRAUGHT PRESSURE (Pa)    12
ELECTRIC CONSUMPTION (Watt)    -
HIGH TEMPERATURE SAFETY THERMOSTAT    -
*A Emissions and performance data may change according to the fuel used. The values of pellet products have been obtained by using certified fuel according to EN 14961-2 A1-A2 norm. Wood logs products values may vary according to the type and quality of the wood logs used.
*B Provisional data under certification
*C IMPORTANT: when calculating the volume of the “Heated area” some relevant aspects must be considered: insulation of the building (Energy Class), position of the heater, climatic area and more aspects that can affect the values of performance. Reported data have been calculated on the base of roof not higher than 3 mts.
The manufacturer reserves the right to make changes without previous notice.
Downloadable docs
Energy Label - Label
Energy Label - Product fiche